Summary for Test 2022-01-21-11-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215108
DEA: 07337604
EFIS: 0717000036
DIST-CO-RTE-PM07-LA-14-R28.9/R29.2
Award Date10/15/2020
Closeout Date05/04/2023
Work DescriptionREPLACE EXISTING STORM DRAIN, AND CONSTRUCT A COLLECTION SYSTEM.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR SANTA CLARITA FROM 0.8 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 02/24/2021)

Sample Information

Sample Taken Date01/21/2022 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2022
Sample typeAcceptance A brief description of the sampleNative Material
The quantity of what the sample constitutes500 sqft From where was the sample collectedJob Site
First name of sampler or witnessed byChad Last name of sampler or witnessed byChotibhongs
Title of samplerMREA Telephone number of sampler213-817-0387
Laboratory sample identification22-0107 Linked DIME Sample ID
The fabricator/manufacturer/facility nameOn-Site Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedCTM 231 test location
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-01-21-11
DIME Test ID: 2022-01-21-11-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-01-25

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 01/25/2022
Gage No.: 60293
Test No.: 3
Nuclear By: Chad Chotibhongs
Non-Bias Plan No.: 8
Depth: 5
Material No.: On-Site
Material Type: Native
Impact By: Chad Chotibhongs
Standard Count Density: 2222 g/cc
Count or Density 1: 2.11 g/cc
Count or Density 2: 2.15 g/cc
Count or Density 3: 2.13 g/cc
Standard Count Moisture: 644 g/cc
Moisture Count 1: 0.15 g/cc
Moisture Count 2: 0.18 g/cc
Moisture Count 3: 0.15 g/cc
Sum of Count or Density: 6.39 g/cc
Average of Count or Density: 2.13 g/cc
Sum of Moisture Count: 0.48 g/cc
Average of Moisture Count: 0.16 g/cc
Calculated Percent Relative Compaction: 97.3 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/25/2022