Summary for Test 2016-03-15-6-1

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/15/2016 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/22/2016
Sample typeQuality Assurance A brief description of the sample.5 Prestressing Strand
The quantity of what the sample constitutes474 From where was the sample collectedFabricator
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)S128907-5, S128910-2, S128910-4, S128913-2, S128917-7, S128922-3, S128922-6, S128923-3, S128924-3, S128927-2, S128927-5, S128928-5, S128928-6, S128929-6, S128932-1, S128934-2, S128935-2, S128936-2, S128936-6, S128939-2, S128940-2, S128941-1, S128941-4, S128943-1, S128943-3 Number of Coils25
Group Number10842 Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0533615-2, S0533815-2, S0599315-2, S0533715-2, S0534015-3, S0524215, S0524315, S0533215, S0533215-2, S0524915-3, S0524815-3, S0524715-3, S0524615, S0524515-5, S0516916 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2016-03-15-6
DIME Test ID: 2016-03-15-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Test Release Date: 2016-03-29

Test Results


Number of Samples: 25
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 03/23/2016
NumDia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
1.172.165.165.165.165.165.1650.152
2.172.165.165.165.165.165.1650.152
3.172.165.165.165.165.165.1650.152
4.172.165.165.165.165.165.1650.152
5.172.165.165.165.165.165.1650.152
6.173.165.165.165.165.165.1650.152
7.173.165.165.165.165.165.1650.152
8.173.165.165.165.165.165.1650.152
9.173.165.165.165.165.165.1650.152
10.173.165.165.165.165.165.1650.152
11.173.165.165.165.165.165.1650.152
12.172.165.165.165.165.165.1650.152
13.172.165.165.165.165.165.1650.152
14.173.165.165.165.165.165.1650.152
15.173.165.165.165.165.165.1650.152
16.172.165.165.165.165.165.1650.152
17.172.165.165.165.165.165.1650.152
18.172.165.165.165.165.165.1650.152
19.172.165.165.165.165.165.1650.152
20.172.165.165.165.165.165.1650.152
21.172.165.165.165.165.165.1650.152
22.172.165.165.165.165.165.1650.152
23.172.165.165.165.165.165.1650.152
24.173.165.165.165.165.165.1650.152
25.173.165.165.165.165.165.1650.152

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/29/2016