Summary for Test 2021-12-01-24-1
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/01/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/07/2022 |
Sample type | Verification | A brief description of the sample | Tank 1234 |
The quantity of what the sample constitutes | 2 of 2, split sample | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Gustavo | Last name of sampler or witnessed by | Moreno |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | 112321-104 | Linked DIME Sample ID | 2021-11-23-27 |
The fabricator/manufacturer/facility name | South Gate, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | 1234 | |
Time of sample | 1230 | HMA Supplier | |
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-12-01-24
DIME Test ID: 2021-12-01-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2022-01-13
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 01/10/2022
Ductility of test #1 (D1): 147 cm
Ductility of test #2 (D2): 135 cm
Ductility of sample: 141 cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/13/2022 ✔