Summary for Test 2021-10-12-45-2
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 8802 DEA: RR-ARB21 EFIS: RR-ARB21 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special Project for Round Robin of Asphalt Rubber Binder 2021 |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/12/2021 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2021 |
Sample type | Informational | A brief description of the sample | Asphalt Rubber Binder Round Robin Sample A |
The quantity of what the sample constitutes | One Gallon Can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Blending Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | Tricor Refining |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-10-12-45
DIME Test ID: 2021-10-12-45-2
Testing Lab: Granite Construction Company - Coastal
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-12-28
Test Results
Input Type: Calculated
Tester's full name: Steven Derpich
Date of test: 12/27/2021
Temperature: 25 C
Final Dial reading (F1): 51 mm
Ball Penetration (P1): 2 mm
Final Dial reading (F2): 55 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 54 mm
Ball Penetration (P3): 1 mm
Resilience 1: 51 %
Resilience 2: 45 %
Resilience 3: 47 %
Average Resilience: 48 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/28/2021 ✔