Summary for Test 2021-09-27-71-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215744
DEA: 033H93U4
EFIS: 0321000091
DIST-CO-RTE-PM03-YUB,BUT-70-25.5/25.8,0.0/3.8
Award Date07/15/2021
Closeout DateNot set
Work DescriptionWIDEN ROADWAY & SHOULDER, ADD TURN LANES & CONSTRUCT BRIDGE.
Location DescriptionYUBA AND BUTTE COUNTIES ABOUT 11 MILES NORTH OF MARYSVILLE FROM 0.8 MILE NORTH OF CHANDLER ROAD TO 0.2 MILE SOUTH OF EAST GRIDLEY ROAD
QA Service Level1 (Verified on 05/20/2021)

Sample Information

Sample Taken Date09/27/2021 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/28/2021
Sample typeVerification A brief description of the sample1/2" Rap
The quantity of what the sample constitutesbags of rap From where was the sample collectedSupplier
First name of sampler or witnessed byKenny Last name of sampler or witnessed byMcHugh
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Aggregates Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTeichert Aggregates
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-27-71
DIME Test ID: 2021-09-27-71-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-12-27

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 09/29/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.20 %
General comments (publicly viewable) (Max 1000 characters): JMF21-039

Test was verified on 12/27/2021