Summary for Test 2021-06-25-21-3
Test performed: ASTM C1064-17Project Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 06/25/2021 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/26/2021 |
Sample type | Quality Control | A brief description of the sample | 6 X 12 Concrete Cylinder |
The quantity of what the sample constitutes | 7 CY | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mauril | Last name of sampler or witnessed by | Mariano |
Title of sampler | Quality Control Engineer | Telephone number of sampler | (925) 382-6048 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | KIE-CON, INC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | K4200 CP1A |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 110807 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | 20-020B 6/25/2021 | |
A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Abutment Cap |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-06-25-21
DIME Test ID: 2021-06-25-21-3
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2021-12-21
Test Results
Input Type: Calculated
Tester's full name: Mauril Mariano
Date of test: 06/25/2021
Temperature: 75 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/21/2021 ✔