Summary for Test 2021-11-03-38-4

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/03/2021 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2021
Sample typeVerification A brief description of the sampleTank 533
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byThomas Last name of sampler or witnessed byLudlum
Title of sampler Telephone number of sampler
Laboratory sample identification21-242 Linked DIME Sample ID2021-11-03-34
The fabricator/manufacturer/facility nameGlendale, AZ Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierHolly Frontier Asphalt Company - Glendale AZ MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-03-38
DIME Test ID: 2021-11-03-38-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-12-20

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 12/15/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 51.239 kPa
Phase Angle (δ) (for the 10 cycles): 47.1 degree
Complex Modulus (G*) (for the 10 measurements): 5123.914 kPa
Test Temperature (Specimen 1): 34.0 C
(G*) x sin(δ)=: 3753 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 12/20/2021