Summary for Test 2019-08-15-18-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date08/15/2019 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/15/2019
Sample typeVerification A brief description of the sampleUntreated 3/8-inch Sized Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byMark Last name of sampler or witnessed byMahoney
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD78105B Linked DIME Sample ID
The fabricator/manufacturer/facility nameJF Shea Construction - Fawndale Rock Quarry - Redding Transportation Laboratory (TL) Number898330
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0017
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberJMF 19-26-S1 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-08-15-18
DIME Test ID: 2019-08-15-18-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-12-14

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Arthur Mills and Colt Sweeny
Date of test: 08/16/2019
Cumulative Mass RetainedCumulative Percent Passing
1616.7 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
174.0 grams89.2 %
901 grams44.3 %
1323.0 grams18.2 %
231.4 grams3.9 %
240.8 grams3.3 %
243.7 grams3.1 %
246.7 grams2.9 %
251.7 grams2.6 %
258.1 grams2.21 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/14/2021