Summary for Test 2021-12-05-2-2

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date12/05/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/05/2021
Sample typeQuality Control A brief description of the sampleTank 10
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byEric Last name of sampler or witnessed byGauss
Title of sampler Telephone number of sampler
Laboratory sample identification120521-470 Linked DIME Sample ID
The fabricator/manufacturer/facility nameWilmington, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number10
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-12-05-2
DIME Test ID: 2021-12-05-2-2
Testing Lab: Valero Marketing & Supply
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-12-13

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: APART Lab
Date of test: 12/13/2021
Observed Flash Point: no data
Ambient Barometric Pressure: no data
Cleveland Open-Cup Flash Point in Celsius: 304 C
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.

Test was verified on 12/13/2021