Summary for Test 2021-11-19-16-5
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214397 DEA: 120N3204 EFIS: 1213000196 |
---|---|
DIST-CO-RTE-PM | 12-ORA-91-R9.8/R18.9 |
Award Date | 11/07/2019 |
Closeout Date | 07/01/2022 |
Work Description | CONST PRECAST SLAB REPLACEMENT, COLD PLANE AC PVMT AND PLACE RHMA. |
Location Description | ORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE |
QA Service Level | 1 (Verified on 12/02/2019) |
Sample Information
Sample Taken Date | 11/19/2021 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/01/2021 |
Sample type | Verification | A brief description of the sample | PSUE 1/2" RHMA-G-SP, 1.0% LAS |
The quantity of what the sample constitutes | 2 Bags of Combined Aggregate | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | All American Asphalt Corona | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0657G-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | All American Asphalt Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0005 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 RHMA-G-SP | The fabricator/manufacturer designation for the sample | |
The plant number | 106836 | A detailed description of where the material sample was collected | Belt Cut at All American Corona Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-19-16
DIME Test ID: 2021-11-19-16-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-12-13
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 12/02/2021
Clay Level (Test 1): 6.2
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.4
Sand Level (Test 2): 3.6
Clay Level (Test 3): 6.2
Sand Level (Test 3): 3.7
Sand Equivalent (Test 1): 63
Sand Equivalent (Test 2): 67
Sand Equivalent (Test 3): 60
Sand Equivalent: 64
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/13/2021 ✔