Summary for Test 2021-11-29-25-1
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 215179 DEA: 010F4704 EFIS: 0116000011 |
---|---|
DIST-CO-RTE-PM | 01-HUM-299-30.7/37.7 |
Award Date | 11/19/2020 |
Closeout Date | 11/27/2023 |
Work Description | PLACE HMA & RHMA-G & CONSTRUCT SOLDIER PILE WALL. |
Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 1.1 MILES WEST OF ROUTE 96 JUNCTION |
QA Service Level | 1 (Verified on 09/15/2020) |
Sample Information
Sample Taken Date | 11/29/2021 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/06/2021 |
Sample type | Acceptance | A brief description of the sample | Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Trena | Last name of sampler or witnessed by | Freitas |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Mercer Fraser | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-29-25
DIME Test ID: 2021-11-29-25-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-12-09
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 12/09/2021
Temperature: 25 C
Final Dial reading (F1): 100 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 100 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 100 mm
Ball Penetration (P3): 0 mm
Resilience 1: 0 %
Resilience 2: 0 %
Resilience 3: 0 %
Average Resilience: 0 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): no rebound
Test was verified on 12/9/2021 ✔