Summary for Test 2021-11-19-20-2

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214397
DEA: 120N3204
EFIS: 1213000196
DIST-CO-RTE-PM12-ORA-91-R9.8/R18.9
Award Date11/07/2019
Closeout Date07/01/2022
Work DescriptionCONST PRECAST SLAB REPLACEMENT, COLD PLANE AC PVMT AND PLACE RHMA.
Location DescriptionORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 12/02/2019)

Sample Information

Sample Taken Date11/19/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/01/2021
Sample typePer Request A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byAAA QC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0657-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-19-20
DIME Test ID: 2021-11-19-20-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-12-23

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Babak Rezaei
Date of test: 12/06/2021
Any material loss from containers during heating process/testing?: Yes
Mass of empty container #1: 166.191 grams
Mass of empty container #2: 169.377 grams
Mass of container #1 before test (m1i): 201.214 grams
Mass of container #2 before test (m2i): 204.748 grams
Mass of container #1 after test (m1f): 201.185 grams
Mass of container #2 after test (m2f): 204.717 grams
Average mass change: -0.085 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/23/2021