Summary for Test 2021-11-23-9-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215236
DEA: 081C6804
EFIS: 0812000343
DIST-CO-RTE-PM08-RIV-74,79and371-Varies
Award Date12/29/2020
Closeout DateNot set
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE, RETAINING WALL AND BOX CULVERT.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/02/2021)

Sample Information

Sample Taken Date11/23/2021 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/29/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R24, 0.5% LAS
The quantity of what the sample constitutes4 Bags of Combined Aggregate, 3 Bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byCalifornia Commercial Asphalt Lake Elsinore Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0650A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalifornia Commercial Asphalt - Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0011, 91-33-0098
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R24 The fabricator/manufacturer designation for the sample
The plant number53417615 A detailed description of where the material sample was collectedBelt Cut at California Commercial Asphalt Lake Elsinore Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-23-9
DIME Test ID: 2021-11-23-9-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-12-01

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 11/30/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 960.8 grams
Mass of the pycnometer with water (B): 653.3 grams
Mass of the oven dried sample (before pycnometer) (A): 489.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489.3 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.542
Bulk specific gravity (SSD Basis): 2.597
Apparent specific gravity: 2.691
Absorption: 2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/1/2021