Summary for Test 2016-02-10-4-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 208967 DEA: 110223U4 EFIS: 1112000102 |
---|---|
DIST-CO-RTE-PM | 11-SD-5,89-R29.1/R30.5 |
Award Date | 12/18/2014 |
Closeout Date | 02/04/2022 |
Work Description | REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT |
QA Service Level | 1 (Verified on 01/21/2015) |
Sample Information
Sample Taken Date | 02/10/2016 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2016 |
Sample type | Quality Assurance | A brief description of the sample | Coupon Casting |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | BCI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 01186, 01196, 01206 |
---|---|---|---|
Part Number (s) | 6827216246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | BCI |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2016-02-10-4
DIME Test ID: 2016-02-10-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-02-22
Test Results
Number of Samples: 6
Input Type: Calculated
Tester's full name: Fred
Date of test: 02/17/2016
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 01186 | 0.493 | 0.1909 | 61052 | 103380 | 9 | Fred | |
2 | 01186 | 0.5 | 0.1963 | 60347 | 102240 | 9 | Fred | |
3 | 01196 | 0.495 | 0.1924 | 54229 | 87430 | 9.7 | Fred | |
4 | 01196 | 0.494 | 0.1917 | 57134 | 91530 | 8.9 | Fred | |
5 | 01206 | 0.5 | 0.1963 | 60433 | 102410 | 11 | Fred | |
6 | 01206 | 0.495 | 0.1924 | 63681 | 106140 | 7.9 | Fred |
General comments (publicly viewable) (Max 1000 characters): All samples failed - Low elongation.
Test Graph
Test was verified on 2/22/2016 ✔