Summary for Test 2021-10-18-45-1

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/18/2021 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2021
Sample typeVerification A brief description of the sample25001
The quantity of what the sample constitutes1 of 4 From where was the sample collectedManufacturer
First name of sampler or witnessed byGabriela Last name of sampler or witnessed byDiaz
Title of sampler Telephone number of sampler
Laboratory sample identification101821-25001 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample8:30AM HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-10-18-45
DIME Test ID: 2021-10-18-45-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-11-30

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 11/19/2021
Ductility of test #1 (D1): 118 cm
Ductility of sample: 118 cm
General comments (publicly viewable) (Max 1000 characters): PER 2018 STANDARD SPECIFICATIONS

Test was verified on 11/30/2021