Summary for Test 2021-10-28-2-8
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213598 DEA: 051F75U4 EFIS: 0518000092 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R36.9/47.7 |
Award Date | 01/16/2019 |
Closeout Date | 01/11/2024 |
Work Description | CRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER |
Location Description | MONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE |
QA Service Level | 1 (Verified on 10/11/2018) |
Sample Information
Sample Taken Date | 10/28/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2021 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A325 Assembly |
The quantity of what the sample constitutes | 300 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Couch |
Title of sampler | METS Rep | Telephone number of sampler | 5304170632 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Tru-fit Products of Utah | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Salinas River Bridge |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | NF12103854 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM A325 | |
Bolt Length(s) | 2 | Nut Specification | n/a |
Washer Specification | n/a | Finish | Mech Galv |
Diameter/Size | 7/8 dia | Bolt Mfg. Lot Number | 323127A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-10-28-2
DIME Test ID: 2021-10-28-2-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-11-18
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 11/17/2021
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 323127A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 N
Size: .875 in
Bolt Length: 2 in
Measurement Average: 2.15 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/18/2021 ✔