Summary for Test 2021-10-28-3-9

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 213598
DEA: 051F75U4
EFIS: 0518000092
DIST-CO-RTE-PM05-MON-101-R36.9/47.7
Award Date01/16/2019
Closeout Date01/11/2024
Work DescriptionCRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER
Location DescriptionMONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE
QA Service Level1 (Verified on 10/11/2018)

Sample Information

Sample Taken Date10/28/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/05/2021
Sample typeQuality Assurance A brief description of the sampleASTM A325 Assembly
The quantity of what the sample constitutes300 From where was the sample collectedJob Site
First name of sampler or witnessed byKevin Last name of sampler or witnessed byCouch
Title of samplerMETS Rep Telephone number of sampler5304170632
Laboratory sample identification Linked DIME Sample ID2021-10-28-2
The fabricator/manufacturer/facility nameTru-fit Products of Utah Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSalinas River Bridge

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)NF11200934 Nut Mfg. Lot Number(s)288594A
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s) Nut SpecificationASTM A563
Washer Specificationn/a FinishMech Galv
Diameter/Size7/8 dia Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-10-28-3
DIME Test ID: 2021-10-28-3-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-11-18

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 11/17/2021
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 288594A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: DH N
Size: .875 in
Bolt Length: no data
Measurement Average: 2.17 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2021