Summary for Test 2021-11-09-16-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215587
DEA: 081L6804
EFIS: 0820000138
DIST-CO-RTE-PM08-RIV-91,15-7.5/13.4,8.2/23.9
Award Date04/30/2021
Closeout Date08/16/2023
Work DescriptionSLAB REPLACEMENT, PLACE SLURRY SEAL AND REPLACE AC SURFACING.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR CORONA AND MURRIETA ON ROUTE 91 FROM ROUTE 15/91 SEPARATION TO 0.4 MILE EAST OF TYLER STREET AND ON ROUTE 15 FROM 1.5 MILES NORTH OF WINCHESTER ROAD TO NICHOLS ROAD
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date11/09/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/12/2021
Sample typeDepartment Acceptance A brief description of the sample3/4" WMA-A-SP R15 0.4% EVO
The quantity of what the sample constitutes2 Boxes HMA 100.78 tons out From where was the sample collectedManufacturer
First name of sampler or witnessed byAAA Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0630A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-11-09-16
DIME Test ID: 2021-11-09-16-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-11-15

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 11/13/2021
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.57 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2021