Summary for Test 2021-10-02-4-1
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/02/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2021 |
Sample type | Verification | A brief description of the sample | Tank 40 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Keven | Last name of sampler or witnessed by | Heitschmidt |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | PG641610221KF40 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Klamath Falls, OR | Transportation Laboratory (TL) Number | Not set |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | Not set | Lot number | Not set |
Sublot number | Not set | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Albina Asphalt | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-10-02-4
DIME Test ID: 2021-10-02-4-1
Testing Lab: Albina Asphalt
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2021-11-11
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Reeve P
Date of test: 11/11/2021
Time of test: no data
Test Temperature: 0 C
Speed: 0 rpm
Spindle size: no data
Torque: 0 %
Viscosity reading #1 (A) : no data
Viscosity reading #2 (B) : no data
Viscosity reading #3 (C): no data
Average viscosity: 0.455 Pa-s
General comments (publicly viewable) (Max 1000 characters): Submitted from ASCP bulk upload.
Test was verified on 11/11/2021 ✔