Summary for Test 2021-09-27-67-2
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215638 DEA: 09387904 |
---|---|
DIST-CO-RTE-PM | 09-INY-190-111.6/126.1 |
Award Date | 05/12/2021 |
Closeout Date | 01/18/2022 |
Work Description | PLACE HMA OVER EXISTING PAVEMENT. |
Location Description | INYO COUNTY NEAR FURNACE CREEK FROM 0.1 MILE WEST OF BAD WATER ROAD TO 3.6 MILES EAST OF DANTE'S VIEW ROAD |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/27/2021 | Sample Unique Key | 67 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/25/2021 |
Sample type | Acceptance | A brief description of the sample | TEST Asphalt Binder, NO TEST 9/28, 9/29, 9/30, 10/4 |
The quantity of what the sample constitutes | 2 CANS | From where was the sample collected | Source |
First name of sampler or witnessed by | WULFENSTEIN | Last name of sampler or witnessed by | WULFENSTEIN |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Ergon | Transportation Laboratory (TL) Number | 661877 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Ergon Asphalt & Emulsions Incorporated - Las Vegas NV | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-27-67
DIME Test ID: 2021-09-27-67-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-11-05
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 11/03/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.291 kPa
Phase Angle (δ) (for the 10 cycles): 85.6 degree
Complex Modulus (G*) (for the 10 measurements): 2.911 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 2.92 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications RTFO
Test was verified on 11/5/2021 ✔