Summary for Test 2021-10-29-2-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 993322 DEA: 010L4204 EFIS: 0122000008 |
---|---|
DIST-CO-RTE-PM | 01-MEN,MEN/MEN-101-4/6, 4.0/6.0 |
Award Date | 08/23/2021 |
Closeout Date | Not set |
Work Description | Landslide Repair near Commisky |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/11/2021) |
Sample Information
Sample Taken Date | 10/29/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2021 |
Sample type | Quality Assurance | A brief description of the sample | 5'6" #8 Flash butt welded hoops |
The quantity of what the sample constitutes | 750 hoops | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 520-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | 2021-10-22-2 | |
The fabricator/manufacturer/facility name | Conco Reinforcing Benicia | Transportation Laboratory (TL) Number | C658236 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-110-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | 3500021175 |
Hoop Manufacturer Lot Number(s) | H16 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #8 |
Diameter of Hoop | 5'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-10-29-2
DIME Test ID: 2021-10-29-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-11-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/02/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 4 | H16 | 8/25mm | 0.79 | 78304.48 | 99120 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/2/2021 ✔