Summary for Test 2021-10-19-12-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
Award Date | 03/22/2018 |
Closeout Date | 07/24/2023 |
Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
Location Description | SFOBB WEST SPAN |
QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
Sample Taken Date | 10/19/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/8 x 5-1/2 A325 Bolts |
The quantity of what the sample constitutes | 50 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Charles | Last name of sampler or witnessed by | Franco |
Title of sampler | CALTRANS QA INSPECTOR | Telephone number of sampler | (858) 583-9270 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 146623-1 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 34664-212165 | |
Washer Mfg. Lot Number(s) | 0220-393 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 5-1/2 | Nut Specification | ASTM A563DH |
Washer Specification | ASTM F436-1 | Finish | HDG |
Diameter/Size | Bolt Mfg. Lot Number | 446594A | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-10-19-12
DIME Test ID: 2021-10-19-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-10-28
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/28/2021
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 446594A | 1.1250 | 112359 | 499.8 | 6.00 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/28/2021 ✔