Summary for Test 2021-10-15-16-10
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/15/2021 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/20/2021 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolts |
The quantity of what the sample constitutes | 1078 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Hasler |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Fontana | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 10569300 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 3" | Nut Specification | na |
Washer Specification | na | Finish | HDG |
Diameter/Size | 1.25" | Bolt Mfg. Lot Number | 816633 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-10-15-16
DIME Test ID: 2021-10-15-16-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-10-28
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 10/26/2021
Sample No.: 1E
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 816633
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: 1.25 in
Bolt Length: 3 in
Measurement Average: 3.8 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/28/2021 ✔