Summary for Test 2021-10-15-17-3
Test performed: CTM 524-March 2013Project Information
Project Identifiers | Project ID: 215587 DEA: 081L6804 EFIS: 0820000138 |
---|---|
DIST-CO-RTE-PM | 08-RIV-91,15-7.5/13.4,8.2/23.9 |
Award Date | 04/30/2021 |
Closeout Date | 08/16/2023 |
Work Description | SLAB REPLACEMENT, PLACE SLURRY SEAL AND REPLACE AC SURFACING. |
Location Description | RIVERSIDE COUNTY IN AND NEAR CORONA AND MURRIETA ON ROUTE 91 FROM ROUTE 15/91 SEPARATION TO 0.4 MILE EAST OF TYLER STREET AND ON ROUTE 15 FROM 1.5 MILES NORTH OF WINCHESTER ROAD TO NICHOLS ROAD |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 10/15/2021 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/15/2021 |
Sample type | Quality Assurance | A brief description of the sample | Concrete beams |
The quantity of what the sample constitutes | 3 beams | From where was the sample collected | Job Site |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 4RA,4RB,4RC | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | SHORTLOAD CONCRETE INC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | CTS 65-EHI |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | TT | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | concrete sample from wheel barrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-10-15-17
DIME Test ID: 2021-10-15-17-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2021-10-20
Test Results
Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: A. Nguyen, K. Patel
Date of test: 10/18/2021
Identification number: 4RC
Width of specimen: 5.9375 inch
Depth of specimen: 6.125 inch
Span length of specimen: 18 inch
Maximum load applied: 8220 lb
Curing history and apparent moisture condition of the specimen: per test method
If specimen was capped, ground or if leather shims were used: no
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 700 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/20/2021 ✔