Summary for Test 2021-09-14-35-2
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/14/2021 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/06/2021 |
Sample type | Verification | A brief description of the sample | binder PG64-16 |
The quantity of what the sample constitutes | 3 cans, initial testing for COC binder program | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Edgard | Last name of sampler or witnessed by | Hitti |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | 2021-09-14-24 | |
The fabricator/manufacturer/facility name | Granite Construction Bakersfield | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 60002 | |
Time of sample | 0800 | HMA Supplier | |
Certified Asphalt Supplier | Granite Construction - Bakersfield CA | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-14-35
DIME Test ID: 2021-09-14-35-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-10-20
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 10/14/2021
Ductility of test #1 (D1): 124 cm
Ductility of sample: 124 cm
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications
Test was verified on 10/20/2021 ✔