Summary for Test 2015-11-24-7-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/24/2015 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/24/2015 |
Sample type | Quality Assurance | A brief description of the sample | strand |
The quantity of what the sample constitutes | 11 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hironaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S3335231 S3335241 S3335253 S3335252 S3772933 | Number of Coils | Unknown |
Group Number | 10813 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | SO556115 SO556215 SO5447152 SO591815 SO544615 | Mfg. Lot Number(s) | 10813 |
Manufacturer(s) | EVRAZ Cascade |
Test Details
DIME Sample ID: 2015-11-24-7
DIME Test ID: 2015-11-24-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Test Release Date: 2015-12-31
Test Results
Number of Samples: 11
Input Type: Measured
Tester's full name: Dave Drane
Date of test: 12/01/2015
Num | Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) |
---|---|---|---|---|---|---|---|---|
1 | .207 | .197 | .197 | .197 | .198 | .197 | .197 | 0.217 |
2 | .207 | .197 | .197 | .197 | .197 | .197 | .198 | 0.217 |
3 | .207 | .197 | .198 | .197 | .198 | .197 | .197 | 0.217 |
4 | .207 | .198 | .197 | .197 | .197 | .198 | .197 | 0.217 |
5 | .207 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 |
6 | .207 | .198 | .198 | .197 | .197 | .197 | .197 | 0.217 |
7 | .207 | .197 | .197 | .197 | .198 | .198 | .197 | 0.217 |
8 | .207 | .197 | .198 | .198 | .198 | .197 | .197 | 0.217 |
9 | .207 | .198 | .197 | .197 | .197 | .198 | .197 | 0.217 |
10 | .207 | .197 | .197 | .197 | .198 | .198 | .197 | 0.217 |
11 | .207 | .198 | .197 | .197 | .198 | .197 | .197 | 0.217 |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/31/2015 ✔