Summary for Test 2021-10-01-18-3

Test performed: AASHTO T315-12

Project Information

Project IdentifiersProject ID: 214523
DEA: 07302504
EFIS: 0713000479
DIST-CO-RTE-PM07-VEN-23-R3.3/R11.5
Award Date02/06/2020
Closeout DateNot set
Work DescriptionPLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING
QA Service Level1 (Verified on 03/17/2020)

Sample Information

Sample Taken Date10/01/2021 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/08/2021
Sample typePer Request A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byVulcan QC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0583-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-10-01-18
DIME Test ID: 2021-10-01-18-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-13

Test Results


Input Type: Calculated
Tester's full name: DavidR Valenzuela
Date of test: 10/13/2021
Phase: Original binder
Phase Angle (δ) (for the 10 cycles): 89.3 degree
Dynamic Shear, G*/sin(δ): 1.32 kPa
(G*) x sin(δ)=: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/13/2021