Summary for Test 2021-10-01-18-3
Test performed: AASHTO T315-12Project Information
Project Identifiers | Project ID: 214523 DEA: 07302504 EFIS: 0713000479 |
---|---|
DIST-CO-RTE-PM | 07-VEN-23-R3.3/R11.5 |
Award Date | 02/06/2020 |
Closeout Date | Not set |
Work Description | PLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT. |
Location Description | VENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 03/17/2020) |
Sample Information
Sample Taken Date | 10/01/2021 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2021 |
Sample type | Per Request | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Vulcan QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0583-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan-Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-10-01-18
DIME Test ID: 2021-10-01-18-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-13
Test Results
Input Type: Calculated
Tester's full name: DavidR Valenzuela
Date of test: 10/13/2021
Phase: Original binder
Phase Angle (δ) (for the 10 cycles): 89.3 degree
Dynamic Shear, G*/sin(δ): 1.32 kPa
(G*) x sin(δ)=: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/13/2021 ✔