Summary for Test 2021-09-23-12-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 215394 DEA: 031H8604 EFIS: 0317000010 |
---|---|
DIST-CO-RTE-PM | 03-BUT-99-29.3/T37.8 |
Award Date | 03/08/2021 |
Closeout Date | 07/07/2023 |
Work Description | INSTALL FIBER OPTIC CABLE SYSTEMS & TRAFFIC MGMT SYSTEM ELEMENTS. |
Location Description | BUTTE COUNTY IN AND NEAR CHICO AT VARIOUS LOCATIONS FROM SOUTHGATE AVENUE TO GARNER LANE |
QA Service Level | 1 (Verified on 01/18/2021) |
Sample Information
Sample Taken Date | 09/23/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1" Heavy Hex Bolt |
The quantity of what the sample constitutes | 330 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 3854470624 |
Laboratory sample identification | na | Linked DIME Sample ID | na |
The fabricator/manufacturer/facility name | Universal Industrial Sales Inc | Transportation Laboratory (TL) Number | na |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-166-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
---|---|---|---|
Heat Number(s) | 58045963 | Nut Mfg. Lot Number(s) | na |
Washer Mfg. Lot Number(s) | na | Bolt Specification | F1554 gr 105 |
Bolt Length(s) | 16-1/2" | Nut Specification | na |
Washer Specification | na | Finish | HDG |
Diameter/Size | 1.0" | Bolt Mfg. Lot Number | 64208-1 |
Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
Test Details
DIME Sample ID: 2021-09-23-12
DIME Test ID: 2021-09-23-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-10-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/11/2021
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | UNC 1 | 0.606 | 88760 | 394 | 146469 | 135673 | 82218 | F1554 Grade 105 |
General comments (publicly viewable) (Max 1000 characters): F1554 Grade 105
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/12/2021 ✔