Summary for Test 2021-09-23-22-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 215394
DEA: 031H8604
EFIS: 0317000010
DIST-CO-RTE-PM03-BUT-99-29.3/T37.8
Award Date03/08/2021
Closeout Date07/07/2023
Work DescriptionINSTALL FIBER OPTIC CABLE SYSTEMS & TRAFFIC MGMT SYSTEM ELEMENTS.
Location DescriptionBUTTE COUNTY IN AND NEAR CHICO AT VARIOUS LOCATIONS FROM SOUTHGATE AVENUE TO GARNER LANE
QA Service Level1 (Verified on 01/18/2021)

Sample Information

Sample Taken Date09/23/2021 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/30/2021
Sample typeQuality Assurance A brief description of the sample1-1/4" x 5", A325 Rocap Assembly
The quantity of what the sample constitutes80 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3854470624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-166-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0133385
Heat Number(s)20372110, 6215105206, 191084 Nut Mfg. Lot Number(s)31634-6215105206
Washer Mfg. Lot Number(s)978 Bolt SpecificationA325
Bolt Length(s)5" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMG
Diameter/Size1-1/4" Bolt Mfg. Lot NumberBM0281
Rocap Test Requirement(s)na Lubricant Requirements(s)Wax and Dye Nuts Only

Test Details

DIME Sample ID: 2021-09-23-22
DIME Test ID: 2021-09-23-22-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/11/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1131634-6215105206150770563fsaylor

General comments (publicly viewable) (Max 1000 characters): 563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/14/2021