Summary for Test 2015-10-22-11-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209135 DEA: 04235844 EFIS: 0400000684 COOP: 042493 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-16.3/17.06 |
Award Date | 06/25/2014 |
Closeout Date | 12/17/2019 |
Work Description | RECONSTRUCT OVERCROSSING, RETAINING WALLS, GROUND IMPROVEMENT, |
Location Description | BURLINGAME |
QA Service Level | 1 (Verified on 10/03/2013) |
Sample Information
Sample Taken Date | 10/22/2015 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/06/2015 |
Sample type | Quality Control | A brief description of the sample | concrete |
The quantity of what the sample constitutes | cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Bryan | Last name of sampler or witnessed by | Nagid |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | unknown | Transportation Laboratory (TL) Number | 055098 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | 57C800 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | unknown |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | cement mixer load 4 | Where the material sample would have been placed if not sampled | retaining wall 205 barrier slab coping |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-10-22-11
DIME Test ID: 2015-10-22-11-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-11-19
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MTM TTO
Date of test: 11/19/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 159860 lb
Maximum load on cylinder 2: 174383 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 5654.8 psi
Compressive strength of cylinder 2: 6146.7 psi
Compressive strength (to nearest 10 psi): 5900 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 11/19/2015 ✔