Summary for Test 2021-09-09-38-2

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date09/09/2021 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2021
Sample typeQuality Control A brief description of the sampleClass II
The quantity of what the sample constitutes3 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byTim Last name of sampler or witnessed byReyes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHanson - Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number63511N0P
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected649659
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedNB HWY 101 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-09-09-38
DIME Test ID: 2021-09-09-38-2
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2021-10-07

Test Results


Number of specimens: 3
Input Type: Calculated
Tester's full name: Tim Reyes
Date of test: 10/07/2021
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): 2
Break Description of Cylinder 2 (if not 'cone'): 2
Break Description of Cylinder 3 (if not 'cone'): 2
Average Compressive Strength (to nearest 10): 4150 lb/in^2
Compressive Strength of Cylinder 1: 2848 lb/in^2
Compressive Strength of Cylinder 2: 4128 lb/in^2
Compressive Strength of Cylinder 3: 4167 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/7/2021