Summary for Test 2021-09-18-3-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
---|---|
DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
Award Date | 03/11/2020 |
Closeout Date | 06/05/2024 |
Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
Location Description | Junction of I-15 and SR-91 in Corona, CA |
QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
Sample Taken Date | 09/18/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/20/2021 |
Sample type | Quality Assurance | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Burton |
Title of sampler | Material Tester | Telephone number of sampler | |
Laboratory sample identification | 1026-918 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | cemex fontana | Transportation Laboratory (TL) Number | 1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 1614705 |
---|---|---|---|
The truck number from where the sample was collected | 10067777 | The batch plant ticket number from where the sample was collected | 29861399 |
Concrete batch plant | CEMEX | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | site | Where the material sample would have been placed if not sampled | I91 WB 2R 3R PIER FOUNDATION LOAD 4 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-09-18-3
DIME Test ID: 2021-09-18-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-10-07
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bahman Baghai
Date of test: 09/25/2021
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 101790 lb
Maximum load on cylinder 2: 97680 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 3623.7 psi
Compressive strength of cylinder 2: 3477.4 psi
Compressive strength (to nearest 10 psi): 3550 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/7/2021 ✔