Summary for Test 2015-11-11-6-7
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 209788 DEA: 034F0704 EFIS: 0314000020 |
---|---|
DIST-CO-RTE-PM | 03-SAC-50-17.1 |
Award Date | 10/31/2014 |
Closeout Date | 11/30/2017 |
Work Description | WIDEN STRUCTURE, EXTEND WEAVE LANE, AND ADD RAMP METERING. |
Location Description | SACRAMENTO COUNTY AT NATOMA OVERHEAD |
QA Service Level | 1 (Verified on 12/26/2014) |
Sample Information
Sample Taken Date | 11/11/2015 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/12/2015 |
Sample type | Quality Assurance | A brief description of the sample | Type II Cement 1 inch Aggs |
The quantity of what the sample constitutes | 10 6x12 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Hayes |
Title of sampler | Assistant SR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Folsom Ready Mix | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Natoma OH |
Material Information
Material Type | Concrete | The concrete mix design number | F850AFST0 |
---|---|---|---|
The truck number from where the sample was collected | 19 | The batch plant ticket number from where the sample was collected | 509501 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Batch plant |
A detailed description of where the material sample was collected | Chute discharge into wheel barrel | Where the material sample would have been placed if not sampled | closure pour |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-11-11-6
DIME Test ID: 2015-11-11-6-7
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-11-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: LMC TTO
Date of test: 11/18/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.95 in
Average diameter of cylinder 2: 5.96 in
Maximum load on cylinder 1: 118087 lb
Maximum load on cylinder 2: 127116 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Cross sectional area of cylinder 1: 27.81 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength of cylinder 1: 4246.2 psi
Compressive strength of cylinder 2: 4556.1 psi
Compressive strength (to nearest 10 psi): 4400 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 11/18/2015 ✔