Summary for Test 2015-11-12-7-2

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date11/12/2015 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/13/2015
Sample typeQuality Assurance A brief description of the sample.6in Prestressing Strand
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byGino Last name of sampler or witnessed byDel Chiaro
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Transportation Laboratory (TL) NumberC927131
Inspector Lot Number from the Transportation Laboratory (TL) FormS0403615 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)S333553-5 Number of Coils1
Group NumberUnknown Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0544615 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden

Test Details

DIME Sample ID: 2015-11-12-7
DIME Test ID: 2015-11-12-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-03-28

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Brian
Date of test: 11/17/2015
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0544615S333553-50.217603675580128.21.71Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 3/28/2016