Summary for Test 2021-09-24-35-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215257 DEA: 11056374 EFIS: 1117000087 |
---|---|
DIST-CO-RTE-PM | 11-SD-11-0.6/2.7 |
Award Date | 02/16/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT INTERCHANGE, PLACE JPCP, HMA, AND INSTALL LIGHTING. |
Location Description | SAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 1.2 MILE EAST OF ENRICO FERMI DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 11/25/2020) |
Sample Information
Sample Taken Date | 09/24/2021 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/05/2021 |
Sample type | Quality Assurance | A brief description of the sample | Erico Lenton Stander Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kieran | Last name of sampler or witnessed by | Fung |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | Erico Lenton | Intermediate Assembler or Fabricator | |
Rebar Size | #14 | Coupler Model | LA-972 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | LA-972 | Rebar Heat Number(s) | 3106596 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-09-24-35
DIME Test ID: 2021-09-24-35-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-10-06
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/06/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID: Large
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 14/43mm | 1 | -0.0014 | 2.25 | 220600 | 98045 | Service Splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 10/6/2021 ✔