Summary for Test 2021-09-22-40-4
Test performed: AASHTO T315-12Project Information
Project Identifiers | Project ID: 214665 DEA: 081G5504 EFIS: 0816000035 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R28.9 |
Award Date | 03/09/2021 |
Closeout Date | 01/18/2022 |
Work Description | REPLACE WEIGH-IN-MOTION SYSTEM WITH HIGH SPEED WEIGH-IN-MOTION SYSTEM. |
Location Description | SAN BERNARDINO COUNTY NEAR NEWBERRY SPRINGS AT 3.6 MILES WEST OF HECTOR ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/22/2021 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/27/2021 |
Sample type | Per Request | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | chris | Last name of sampler or witnessed by | L |
Title of sampler | Vulcan QC | Telephone number of sampler | |
Laboratory sample identification | 0548-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Oro Grande | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-22-40
DIME Test ID: 2021-09-22-40-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-30
Test Results
Input Type: Calculated
Tester's full name: Babak Rezaei
Date of test: 09/29/2021
Phase: RTFO residue
Phase Angle (δ) (for the 10 cycles): 64.8 degree
Dynamic Shear, G*/sin(δ): 2.32 kPa
(G*) x sin(δ)=: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/30/2021 ✔