Summary for Test 2021-09-22-33-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215168
DEA: 101C5004
EFIS: 1016000026
DIST-CO-RTE-PM10-SJ-4,5-T15.5/R16.7,25.8/26.5
Award Date12/09/2020
Closeout Date09/14/2023
Work DescriptionCONSTRUCT JPCP, CRCP, AND APPROACH SLABS.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON ON ROUTE 4 FROM 0.2 MILE EAST OF FRESNO AVENUE TO EL DORADO STREET AND ON ROUTE 5 FROM TAYLOR STREET OVERHEAD TO STOCKTON CHANNEL VIADUCT
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date09/22/2021 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/27/2021
Sample typeQuality Assurance A brief description of the sample#5 Lenton Formsavers
The quantity of what the sample constitutes150 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byJose
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Transportation Laboratory (TL) NumberC923935
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Lenton Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelLenton Formsaver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L9758 Rebar Heat Number(s)6025388
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-09-22-33
DIME Test ID: 2021-09-22-33-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-28

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/27/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 5/16mm100.312836091485Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/28/2021