Summary for Test 2021-09-16-15-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 215552
DEA: 051N1904
EFIS: 0520000149
DIST-CO-RTE-PM05-SB-192-7.0/13.7
Award Date04/27/2021
Closeout Date09/02/2022
Work DescriptionCOLD PLANE AND OVERLAY EXISTING ROADWAY WITH RHMA (GAP GRADED).
Location DescriptionSANTA BARBARA COUNTY AT VARIOUS LOCATIONS FROM COLD SPRING ROAD TO 0.9 MILE WEST OF NIDEVER ROAD
QA Service Level1 (Verified on 03/12/2021)

Sample Information

Sample Taken Date09/16/2021 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/21/2021
Sample typeAcceptance A brief description of the sampleRubberized PG64-16
The quantity of what the sample constitutes1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byN Last name of sampler or witnessed byB
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Transportation Laboratory (TL) Numberc843849
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1
Sublot number1 Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-16-15
DIME Test ID: 2021-09-16-15-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-09-24

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 09/23/2021
Temperature: 25 C
Final Dial reading (F1): 70 mm
Ball Penetration (P1): 1 mm
Final Dial reading (F2): 68 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 69 mm
Ball Penetration (P3): 0 mm
Resilience 1: 31 %
Resilience 2: 32 %
Resilience 3: 31 %
Average Resilience: 31 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications