Summary for Test 2021-09-09-27-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
Award Date | 05/01/2019 |
Closeout Date | 02/22/2024 |
Work Description | Not set |
Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 09/09/2021 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/17/2021 |
Sample type | Department Acceptance | A brief description of the sample | 64-28M |
The quantity of what the sample constitutes | 2 Cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | C |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Perkins | Transportation Laboratory (TL) Number | c799129 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | 6 |
Sublot number | 20 | Tank number | |
Time of sample | HMA Supplier | Teichert Perkins | |
Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-09-27
DIME Test ID: 2021-09-09-27-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-10-06
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 09/23/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 158.399 grams
Mass of empty container #2: 175.717 grams
Mass of container #1 before test (m1i): 193.561 grams
Mass of container #2 before test (m2i): 211.048 grams
Mass of container #1 after test (m1f): 193.34 grams
Mass of container #2 after test (m2f): 210.828 grams
Average mass change: -0.626 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 10/6/2021 ✔