Summary for Test 2021-09-09-12-2
Test performed: CTM 524-March 2013Project Information
Project Identifiers | Project ID: 215612 DEA: 081L6904 EFIS: 0820000139 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10,60-9.9/R24.2,R0.0/R4.6 |
Award Date | 05/06/2021 |
Closeout Date | 10/13/2022 |
Work Description | INDIVIDUAL SLAB REPLACEMENT. |
Location Description | SAN BERNARDINO COUNTY ON ROUTE 10 FROM ROUTE 15 TO ROUTE 215 AND ON ROUTE 60 FROM 0.1 MILE EAST OF RESERVOIR STREET UNDERCROSSING TO EUCLID AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/09/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/10/2021 |
Sample type | Quality Assurance | A brief description of the sample | PCC Rapid set beams |
The quantity of what the sample constitutes | 3 beams | From where was the sample collected | Job Site |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 19RA,19RB,19RC | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Myers and Sons Construction | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 800-3RSC |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | TTI | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | On Job Site at Concrete Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-09-09-12
DIME Test ID: 2021-09-09-12-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2021-09-12
Test Results
Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: K. Talati, R. Osorio
Date of test: 09/12/2021
Identification number: 19RB
Width of specimen: 6 inch
Depth of specimen: 6.1875 inch
Span length of specimen: 18 inch
Maximum load applied: 9565 lb
Curing history and apparent moisture condition of the specimen: moist, curing room
If specimen was capped, ground or if leather shims were used: no
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 790 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/12/2021 ✔