Summary for Test 2021-09-02-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/02/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/09/2021
Sample typeStock A brief description of the sample1 1/2"-6 ASTM A563-DH HHN
The quantity of what the sample constitutes4500 Hex Nuts From where was the sample collectedSupplier
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Circle Corp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-156-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)201522 Nut Mfg. Lot Number(s)DECR
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationASTM A563 Gr. DH
Washer SpecificationN/A FinishHDG
Diameter/Size1 1/2" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-09-02-2
DIME Test ID: 2021-09-02-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-09-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/10/2021
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11DECR247042A563 / A194fsaylor

General comments (publicly viewable) (Max 1000 characters): A563 / A194
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/14/2021