Summary for Test 2021-08-26-13-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 215448
DEA: 031G7404
EFIS: 0319000238
DIST-CO-RTE-PM03-SAC-50-Var
Award Date03/12/2021
Closeout Date03/02/2022
Work DescriptionREMOVE BOLTS AND ADD PAINTED STRUCTURAL STEEL PLATES.
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO AT SACRAMENTO RIVER VIADUCT AND RAMP A4
QA Service Level1 (Verified on 02/19/2021)

Sample Information

Sample Taken Date08/26/2021 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/02/2021
Sample typeQuality Assurance A brief description of the sample7/8" A325 fastener assemblies
The quantity of what the sample constitutes33 each From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler5103767155
Laboratory sample identification Linked DIME Sample ID2021-08-26-7
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) Numberc658227
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-041-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)435991A
Heat Number(s)bolt-100202821 washer- 209071 nut- 453592B Nut Mfg. Lot Number(s)Nucor- 453592B
Washer Mfg. Lot Number(s)Wrought- 10444 9874 Bolt SpecificationA325
Bolt Length(s)5.5" Nut SpecificationA563DH
Washer SpecificationF436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot NumberNucor- 435991A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2021-08-26-13
DIME Test ID: 2021-08-26-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-09-09

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/08/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11453592B72742A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/9/2021