Summary for Test 2015-09-13-1-5
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 210749 DEA: 081G5114 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-57.6/127.0, R57.6-R127.0, R57.6/R127 |
Award Date | 08/07/2015 |
Closeout Date | 03/15/2016 |
Work Description | Secure bridges and build a crossover at Tex Wash |
Location Description | In Riverside County from Jct 86/10 to Arco Ditch |
QA Service Level | 1 (Verified on 08/13/2015) |
Sample Information
Sample Taken Date | 09/13/2015 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/15/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 14 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | VICTOR AMIT | Last name of sampler or witnessed by | WAMI JOSHI |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 920-03 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 3 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | I 10 TEX WASH BRIDGE REPLACE |
Structure name | DECK AND APPROACH SLABS |
Material Information
Material Type | Concrete | The concrete mix design number | 9430DHER |
---|---|---|---|
The truck number from where the sample was collected | NP | The batch plant ticket number from where the sample was collected | NP |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-09-13-1
DIME Test ID: 2015-09-13-1-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-10-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/12/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 177450 lb
Maximum load on cylinder 2: 178310 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 29 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6277.0 psi
Compressive strength of cylinder 2: 6307.4 psi
Compressive strength (to nearest 10 psi): 6290 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/12/2015 ✔