Summary for Test 2021-07-29-32-6
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R9.7 |
Award Date | 04/03/2020 |
Closeout Date | 06/06/2024 |
Work Description | PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/05/2020) |
Sample Information
Sample Taken Date | 07/29/2021 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2021 |
Sample type | Verification | A brief description of the sample | JMF 1/2" HMA-A-SP R15, 0.25% Evotherm |
The quantity of what the sample constitutes | 8 Bags of Aggregate, 1 Bag of RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Vulcan Sun Valley | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0475A-21 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035::FISH CANYON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | |
The plant number | 320914 SVA LTR | A detailed description of where the material sample was collected | Belt Cut at Vulcan Sun Valley Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-29-32
DIME Test ID: 2021-07-29-32-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-09-01
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 08/24/2021
Bulk dry specific gravity: 2.671
Average uncompacted voids: 46.7 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/1/2021 ✔