Summary for Test 2021-08-20-8-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 215371 DEA: 042W1204 EFIS: 0421000139 |
---|---|
DIST-CO-RTE-PM | 04-CC,CC/MRN-580-6.9/7.8, 6.9, 7.8, 02, 5 |
Award Date | 01/11/2020 |
Closeout Date | 09/06/2022 |
Work Description | REPLACEMENT OF GUSSET PLATES AT VARIOUS LOCATIONS |
Location Description | Richmond San Rafael Bridge |
QA Service Level | 1 (Verified on 12/14/2020) |
Sample Information
Sample Taken Date | 08/20/2021 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/25/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/8x4-1/4 A325 HSB Assy - nut |
The quantity of what the sample constitutes | 600 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Couch |
Title of sampler | smr | Telephone number of sampler | 5304170632 |
Laboratory sample identification | Linked DIME Sample ID | 2021-08-20-7 | |
The fabricator/manufacturer/facility name | LeJeune Bolt Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | RSRB |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1414447 |
---|---|---|---|
Heat Number(s) | 75075848 | Nut Mfg. Lot Number(s) | 30727-75075848 |
Washer Mfg. Lot Number(s) | na | Bolt Specification | na |
Bolt Length(s) | na | Nut Specification | ASTM A563 Gr DH |
Washer Specification | na | Finish | ASTM B695 Class 55 Mech Galv |
Diameter/Size | 1-1/8 inch | Bolt Mfg. Lot Number | na |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-08-20-8
DIME Test ID: 2021-08-20-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-08-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/27/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 30727-75075848 | 118313 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/31/2021 ✔