Summary for Test 2021-07-22-17-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
Award Date | 09/23/2020 |
Closeout Date | Not set |
Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/01/2020) |
Sample Information
Sample Taken Date | 07/22/2021 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2021 |
Sample type | Quality Assurance | A brief description of the sample | (2) 6"x12" Cylinders |
The quantity of what the sample constitutes | (2) 6"x12" Cylinders | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Shrestha |
Title of sampler | Inspector | Telephone number of sampler | 4242987781 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Con-Fab California, LLC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L108-006-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SCC S9 8 0F |
---|---|---|---|
The truck number from where the sample was collected | 121 | The batch plant ticket number from where the sample was collected | 1450 |
Concrete batch plant | SPC onsite batch plant | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | At pour location | Where the material sample would have been placed if not sampled | Girder |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-07-22-17
DIME Test ID: 2021-07-22-17-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-08-19
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 08/19/2021
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.99 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 252170 lb
Maximum load on cylinder 2: 242970 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 8920.1 psi
Compressive strength of cylinder 2: 8622.1 psi
Compressive strength (to nearest 10 psi): 8770 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/19/2021 ✔