Summary for Test 2021-08-04-1-3
Test performed: ASTM C39-18
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 215359 DEA: 081K1904 EFIS: 0818000207 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-16.1/169.4 |
Award Date | 02/05/2021 |
Closeout Date | 07/27/2022 |
Work Description | REMOVE, PREPARE AND FURNISH POLYESTER CONC OVERLAY & BRIDGE DECK. |
Location Description | SAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT VARIOUS LOCATIONS FROM CAJON CREEK TO MICRO DITCH. |
QA Service Level | 1 (Verified on 03/30/2021) |
Sample Information
Sample Taken Date | 08/04/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2021 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Bonar |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | 1030-84 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Holliday | Transportation Laboratory (TL) Number | 1003-84 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | NA |
---|---|---|---|
The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | 84 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | SITE | Where the material sample would have been placed if not sampled | Roy Rogers Drive OC |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-08-04-1
DIME Test ID: 2021-08-04-1-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-08-11
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/11/2021
Average diameter of cylinder 1: 5.89 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 133945 lb
Maximum load on cylinder 2: 133980 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.25 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4915.4 psi
Compressive strength of cylinder 2: 4739.3 psi
Compressive strength (to nearest 10 psi): 4830 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/11/2021 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.