Test 2021-06-15-57-1 (ASTM C39-10) Summary

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.
Project Information
Project IdentifiersProject ID: 214114
DEA: 040A5394
EFIS: 0418000244
DIST-CO-RTE-PM04-SOL-80,12-11.4/12.8, 2.1/2.8
Work DescriptionWiden EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location DescriptionI-80/I-680/Route 12 Interchange
Sample Information
Sample Taken Date6/15/2021 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/16/2021
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders (set 5 of 8)
The quantity of what the sample constitutes1305 CY From where was the sample collectedJob Site
First name of sampler or witnessed byCoby Last name of sampler or witnessed byHarris
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCemex Cordelia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeConcrete The concrete mix design number1615776
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected29693199
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-06-15-57
DIME Test ID: 2021-06-15-57-1
Testing Lab: Construction Testing Services
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-08-05
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ryan Ring
Date of test: 07/13/2021
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 217960 lb
Maximum load on cylinder 2: 198700 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1:28.27 in^2
Cross sectional area of cylinder 2:28.27 in^2
Compressive strength (to nearest 10 psi):7370 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/05/2021

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.