Summary for Test 2021-06-22-47-2
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 213856 DEA: 112888U4 EFIS: 1118000199 |
---|---|
DIST-CO-RTE-PM | 11-SD-11,125,905-Various |
Award Date | 05/09/2019 |
Closeout Date | 09/14/2023 |
Work Description | CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY |
Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 06/22/2021 | Sample Unique Key | 47 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/02/2021 |
Sample type | Authorization | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Johnson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Transpo Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | B0623217010 |
---|---|---|---|
Batch number | B0623217010 | Mix number | 3529 |
Test Details
DIME Sample ID: 2021-06-22-47
DIME Test ID: 2021-06-22-47-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-07-28
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 07/21/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 23.6
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.01
Volatile content (ASTM D 2369) 30% max: 28
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 690
Tack free time, 400 minutes max: 392
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/28/2021 ✔