Summary for Test 2021-07-06-18-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 07/06/2021 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/23/2021 |
Sample type | Department Acceptance | A brief description of the sample | A325 HDG Ro-cap |
The quantity of what the sample constitutes | 341 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Chuck | Last name of sampler or witnessed by | Franco |
Title of sampler | QA | Telephone number of sampler | (858) 583-9270 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cascade Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S73-008-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | R453612A |
---|---|---|---|
Heat Number(s) | R453612A, 449804A, 0920-584 | Nut Mfg. Lot Number(s) | 449804A |
Washer Mfg. Lot Number(s) | 0920-584 | Bolt Specification | A325 |
Bolt Length(s) | 4-1/4" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | ASTM A153 |
Diameter/Size | 7/8-9" | Bolt Mfg. Lot Number | 453612A |
Rocap Test Requirement(s) | ASTM F3125 | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-07-06-18
DIME Test ID: 2021-07-06-18-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-07-28
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/27/2021
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 453612A | 0.8750 | 66972 | 297.91 | 10.00 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/28/2021 ✔